Specifications and ratings
Environmental range
The wireless transceiver’s working range is the following
1. Humidity
a. 0-99% humidity for normal operation.
b. Long term exposure to high levels of humidity may cause unexpected behavior in device.
2. Temperature
a. Recommended operating range is 0-40°C
b. Absolute minimum and maximum temperatures are -20°C and 60°C. Functionality may be
lost at extreme temperatures
Handling and installation
The transceivers rugged enclosure ensures a good protection against damage. The enclosure does not
protect external components such as antennas, wiring and cables, on/off switch and LED.
The enclosure is designed to withstand spraying water from vertical downward direction (up to 60° from
vertical alignment). Orientation of the transceiver should therefore be vertical for maximum protection as
demonstrated in the image to the right.
Cleaning of transceivers should be done with neutral soap to prevent rubber sealing, buttons and LEDs
from failing. In case of a need to sanitize or sterilize, use alcohol based compounds and wipe with cloth.
Mounting orientation
The wireless transceiver can be mounted to a surface by using screws or bolts as shown in Figure 5. Screws
and bolts must be chosen according to the mounting surface. The transceiver weighs 370 g. Care must be
taken that screws and bolts can handle the weight for the given surface type. Improper mounting and
installation can cause the transceiver to fall from its intended position and cause harm to nearby people. To
lower risk of harm due to improper installation, installation should be carried out by a qualified person.